I set up my ac trane xl20i 3 ton w trane xv80 dip switches properly for a 3 ton unit at 350 cfm with comfort r enabled.
Am i allowed to seal my attic in florida.
Let s say you measured your attic and you realize your attic has about 9 inches r 30 of insulation and your attic is about 40 sq feet you d need at least 3 inches of extra insulation that covers 40 sq ft to get an r value of r 38.
For larger holes filler material may be needed.
To seal these openings use caulk or spray foam.
The final step is attic ventilation.
The typical method for ventilating the attic on an average home is soffit and ridge vent.
Attics with pull down attic stairs should have attic stair insulation covers installed.
An improved two zone attic model parker et al 1991 used in the fsec 3 0 program accounts for detailed radiation buoyancy and wind driven airflows and.
I suspect the thinking was the more the better.
I ve read where this disrupts the natural flow up from the soffits due to old turbines and new ridge vent.
An early attic model fairey and swami 1992 used primarily for modeling the performance of attic radiant barrier systems treated the attic as two zones an upper zone and a lower zone.
The bigger the attic the more insulation you ll need to purchase.
Spray foam insulation is designed to seal air leaks and to keep out water and mold.
I come across many homes that originally had soffit venting and wind turbines at the peak but continuous ridge venting was added later during a re roof.
The result was a huge improvement the humidity dropped from as high as 70 down around 55 with the a c running all day.
And that depends on the size of your attic space.
It s easy to overlook electrical wires ducts pipes and vents in the attic but the openings around these are holes can compromise the air sealing of your attic.
More specifically whether or not i should be allowed to break the seal if you re not sure what i m talking about here s a photo of an attic access panel.
The size of your attic.
Should i do anything about my attic ventilation.
Seal attic floor holes.
One of the biggest sources of contention that i regularly deal with during inspections of newer houses is whether or not a sealed attic access panel should be broken to access the attic.
Then the researchers drilled 100 half inch leak holes into half of the roofs and left the roofs exposed to natural weather conditions plus 150.
Also the bigger the space the longer it will take to install the insulation making the job more.
Central fl and have a question about humidity control.
Its properties make it an excellent choice for attic insulation.
The roofs got a spray foam underside application in various thicknesses.
I live in a shady area and now there is not as much.
If the attic has blown in cellulose check to see if there is a vapor barrier and confirm the cellulose insulation is spread evenly throughout the attic floor.
The team built five full scale attic structures at the university of florida s hurricane research laboratory in gainesville.